N7527–10 1/00
6/
6HF XULW\6\VWHP
8VHU·V*XLGH
1
2
3
654
897
0
*
#
OFF
AWAY STAY
MAX TEST BYPASS
INSTANT
CODE CHIME
READY
ARMED
READY
1
2
3
654
897
0
*
#
OFF
AWAY STAY
MAX TEST BYPASS
INSTANT
CODE CHIME
READY
ARMED
READY
Vista de página 0
1 2 3 4 5 6 ... 59 60

Resumo do Conteúdo

Página 1 - 6HF XULW\6\VWHP

N7527–10 1/006/6HF XULW\6\VWHP8VHU·V*XLGH1236548970*#OFFAWAY STAYMAX TEST BYPASSINSTANTCODE CHIMEREADYARMEDREADY1236548970*#OFFAWAY STAYMAX TES

Página 2

- 10 -About the KeypadsIMPORTANTIf the keypad beeps rapidly when you enter the premises, it meansthat an alarm has occurred during your absence and an

Página 3 - TABLE OF CONTENTS

- 11 -About the Keypads (cont'd)1236548970*#OFFAW AY S TAYMAX TEST BYPASSINSTANTCODE CHIMEREADYARMEDREADYABCDFIXED-WORD KEYPAD1236548970*#OFFAWAY

Página 4 - (cont'd)

- 12 -About the Keypads (cont'd)NOT READY: The burglary portion of the system is not ready for arming (due toopen protection zones).READY: The b

Página 5 - Burglary Protection

- 13 -Functions of the Keypads1236548970*#OFFAWAY STAYMAX TEST BYPASSINSTANTCODE CHIMEREADYARMEDREADY161415ABCD17811121323514710691.DISPLAY WINDOW: Fi

Página 6 - Fire Protection

- 14 -Functions of the Keypads (cont'd)5.4 MAX KEY: Completely arms bothperimeter and interior burglary zones forfull protection. Entrance t

Página 7 - Paging Feature

- 15 -Checking for Open ZonesUsing the ✱ READY KeyBefore arming your system, all protected doors, windows, and other protectionzones must be closed o

Página 8

- 16 -Arming Perimeter Only(with Entry Delay on)Using the 3 STAY KeyUse this key when you are staying home, but expect someone to use theentrance

Página 9 - Exit Alarms

- 17 -Arming Perimeter Only(with Entry Delay off)Using the 7INSTANT KeyUse this key when you are staying home, but would like increased security byar

Página 10 - Fixed-Word Keypad

- 18 -Arming Perimeter Only (with Entry Delay on or Entry Delay off)Using the 2 AWAY or 4 MAX KeyWhen no one will be staying on the premise

Página 11 - Fixed-Word Keypad Display

- 19 -Disarming and Silencing AlarmsUsing the 1 OFF KeyUse the OFF key to disarm the system and to silence alarm and troublesounds. See Summary

Página 13 - Functions of the Keypads

- 20 -Disarming and Silencing Alarms (cont'd)To clear the display after silencing an alarm:2.ALARM 03 BACKDOORListen for 1 beep.The keypad displ

Página 14 - Notifications

- 21 -Bypassing Protection ZonesUsing the 6 BYPASS KeyThis key is used when you want to arm your system with one or more zonesintentionally unprotecte

Página 15 - Checking for Open Zones

- 22 -Bypassing Protection Zones (cont'd)Quick BypassYour system may allow you to easily bypass all open (faulted) zones withouthaving to enter z

Página 16 - (with Entry Delay on)

- 23 -Chime ModeUsing the 9 CHIME KeyYour system can be set to alert you to the opening of a door or window† whenthe system is disarmed by using the

Página 17 - Arming Perimeter Only

- 24 -Panic Keys(For Manually Activating Silent and/or Audible Alarms)Using Panic KeysYour installer may have programmed your system to use special ke

Página 18

- 25 -Macro KeyUsing a Macro KeyThe “C” key can be used to activate a series of commands of up to 16keystrokes. These keystrokes, as a group, are cal

Página 19 - Using the

- 26 -Using Device CommandsGeneral InformationYour system may be set up so that certain lights or other devices can be turnedon or off by using the de

Página 20 - Memory of Alarm

- 27 -Paging FeaturesGeneral InformationIf the Paging feature has been programmed for your system, up to two separatepagers will automatically respond

Página 21 - Bypassing Protection Zones

- 28 -Using the KeyswitchGeneralYour system may be equipped with a keyswitch for use when arming anddisarming. A red and green light on the keyswitch

Página 22 - Displaying Bypassed Zones

- 29 -Security CodesGeneral InformationAs an additional safety feature, other users who do not need to know your codecan be assigned different securit

Página 23 - Chime Mode

- 3 -TABLE OF CONTENTSSystem Overview...5General Information...5Zones...

Página 24 - Types of Panic Alarms

- 30 -Security Codes (cont'd)Single-Button ArmingYou can arm the system without the need to enter a security code by pressing asingle key on the

Página 25 - Using a Macro Key

- 31 -Security Codes (cont'd)To Change the Master CodeFollow the procedure for changing a user's code, but enter user 02.Additionally, when

Página 26 - Using Device Commands

- 32 -Testing the System(To be conducted weekly)Using the 5 TEST KeyThe TEST key puts your system into a TEST mode, which allows eachprotection point

Página 27 - Code Format

- 33 -Testing the System (cont'd)The display will clear when no motion isdetected. Note that if you are using wirelessmotion detectors, there is

Página 28 - Using the Keyswitch

- 34 -Trouble ConditionsTypical Check DisplaysThe word CHECK on the keypad's display, accompanied by a rapid beeping atthe keypad, indicates a tr

Página 29 - Duress Code

- 35 -Trouble Conditions (cont'd)Telco Fault(or CHECK and zone 94)If the telephone line monitor feature has beenprogrammed for your system, this

Página 30 - Security Codes (cont'd)

- 36 -Trouble Conditions (cont'd)POWER indicator (ifpresent) is off. ACLOSS is displayed.The system is operating on battery power only. Ifonly s

Página 31

- 37 -Fire Alarm System (If Installed)General InformationYour fire alarm system (if installed) is active 24 hours a day, providingcontinuous protecti

Página 32 - (To be conducted weekly)

- 38 -Recommendations for Proper ProtectionTHE FOLLOWING RECOMMENDATIONS FOR THE LOCATION OF FIRE ANDBURGLARY DETECTION DEVICES HELP PROVIDE PROPER CO

Página 33 - (Security Code)

- 39 -Recommendations for Proper Protection (cont'd)In addition, we recommend the following:• Install a smoke detector inside every bedroom where

Página 34 - Typical Check Displays

TABLE OF CONTENTS (cont'd)- 4 -Paging Feature...27General Information ...

Página 35 - CALL FOR SERVICE AT ONCE

- 40 -Emergency EvacuationEstablish and regularly practice a plan of escape in the event of fire. The following steps arerecommended by the National F

Página 36

- 41 -Maintaining Your SystemTaking Care of Your SystemThe components of your security system are designed to be as maintenance-freeas possible. Howev

Página 37 - (If Installed)

- 42 -Maintaining Your System (cont'd)Silencing Low Battery Warning Tones at the KeypadYou can silence the keypad’s warning tones by pressing the

Página 38

- 43 -Quick Guide to System FunctionsFunction ProcedureCommentsCheck ZonesPress [✱]Do this to view zones that are faulted whensystem is “not ready”.Ar

Página 39

-44 -Summary of Audible Notifications(Alpha Display Keypads)SOUND CAUSE DISPLAYLOUD, INTERRUPTED*Keypad & ExternalFIRE ALARMFIRE is displayed; des

Página 40 - Emergency Evacuation

- 45 -GlossaryARM/DISARM: "Armed" simply means that the burglary portion of your system isturned ON and is in a state of readiness. "Di

Página 41 - Taking Care of Your System

- 46 -UL NOTICE: This is a "GRADE A" system.FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 15 STATEMENTThis equipment has been tested to FCC r

Página 42 - Routine Care

- 47 -FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 68 NOTICEThis equipment complies with Part 68 of the FCC rules. On the front cover of this equipmen

Página 43 - Comments

- 48 -CANADIAN DEPARTMENT OF COMMUNICATIONS (DOC) STATEMENTNOTICEThe Canadian Department of Communications label identifies certified equipment. This

Página 44 - (Alpha Display Keypads)

- 49 -WARNING!THE LIMITATIONS OF THIS ALARM SYSTEMWhile this system is an advanced design security system, it does not offer guaranteed protectionagai

Página 45 - Glossary

- 5 -System OverviewGeneral InformationCongratulations on your ownership of a security system. You've made a wisedecision in choosing this system

Página 46

- 50 -WARNING!THE LIMITATIONS OF THIS ALARM SYSTEM (cont'd)• Alarm warning devices such as sirens, bells or horns may not alert people or wake up

Página 47

- 51 -OWNER’S INSURANCE PREMIUM CREDIT REQUEST This form should be completed and forwarded to your homeowner’s insurance carrier for possible premiu

Página 48

- 52 -OWNER’S INSURANCE PREMIUM CREDIT REQUEST(cont'd) E. SMOKE DETECTOR LOCATIONS Furnace Room Kitchen Bedrooms At

Página 49 - WARNING!

- 53 -INDEX[#] Key...30[✱] Key ...15 4-Digit Co

Página 50

- 54 -INDEX (cont’d)Fire Protection...6Fire Zone...21Fixed-W

Página 51 - A. GENERAL INFORMATION:

- 55 -INDEX (cont’d)Trouble Conditions...34Trouble Sounds ...19Two-line Alpha Ke

Página 52

- 56 -Appendix – Macro Key Programming & UsageAbout the Macro Key (C key)The “C” key can be used to automatically activate a series of commands of

Página 53

Appendix – Macro Key Programming & Usage (Continued)- 57 -SPEED LEARN MODEThis prompt will be displayed.3. Enter the first of the series of desire

Página 54 - INDEX (cont’d)

Appendix – Macro Key Programming & Usage (Continued)- 58 -This provides entry into the “Speed Learn Mode” with its accompanyingdisplay.SPEED LEARN

Página 55

Appendix – Macro Key Programming & Usage (Continued)- 59 -How to Use Your Macro Key after You Have Programmed ItTo initiate a macro at any time wh

Página 56 - Security Codes

- 6 -System Overview (cont'd)The following table lists the three different arming modes and the features ofeach.FEATURES OF EACH ARMING MODEARMIN

Página 57 - (arming command)

N7527-10 1/00ONE YEAR LIMITED WARRANTYAlarm Device Manufacturing Company, a Division of Pittway Corporation, and its divisions, subsidiariesand affi

Página 58

-7-System Overview (cont'd)Paging FeatureIf the paging feature has been programmed for your system, up to two pagerswill respond to certain condi

Página 59 - ENTER USER CODE

- 8 -Entry/Exit DelaysGeneral InformationThis system has preset time delays, known as exit delay and entry delay.Whenever you arm your system, exit de

Página 60 - ¬15l

- 9 -Entry/Exit Delays (cont'd)Exit AlarmsTo minimize false alarms sent to the alarm monitoring company,your system may have been programmed for