SL150 Installation and Setup Guide
7–4
Wiring Connections
To wire the Powerline Carrier Device to the control panel, perform the following steps:
1. Splice one end of a 3-conductor cable to the wire ends of the 4142TR Cable supplied with
the 4300 Transformer.
2. Connect the 4142TR Cable Plug to the 9-pin connector on the control (see Figure 24.
Summary of Connections diagram for location of the 9-pin connector).
3. Connect the other end of the 3-conductor cable to the 4300 Transformer, as indicated in
the table below and in the diagram that follows.
4300 TRANSFORMER WIRE CONNECTIONS
4300 Terminal To Terminal on Control
1 (AC) 1 (16.5V AC in)
2 (Ground) 25 Earth Ground terminal
3 (AC) 2 (16.5V AC in)
4300 Terminal 4142TR Cable Wire
4 (Sync) RED (Pin 5 of 9-pin connector)
5 (Data) VIOLET (Pin 1 of 9-pin connector)
6 (Com) WHITE (Pin 4 of 9-pin connector)
123456789
9-PIN CONNECTOR
ON CONTROL BOARD
BLACK
BLUE
BROWN
GREEN
RED
WHITE
YELLOW
GRAY
VIOLET
4142TR CABLE
1
2
3
4
56
125 2
AC
Earth
Ground
AC
Sync
Data
Com
4300 TRANSFORMER/INTERFACE
TERMINALS
ON CONTROL
BOARD
THESE WIRES (7, 8, 9) NOT USED
Figure 18. 4300 Transformer Wiring Connections
Programming Relay Outputs
In the SL150, each device must be programmed as to how to act (ACTION), when to activate
(START), and when to deactivate (STOP). Refer to the programming procedures for
80 and
81 interactive modes that are provided in Section 13: Mechanics of Programming,
Section 17: Output Device Programming, and Section 18: Zone Lists for specific
programming details.