Section 15 -Data Field Descriptions
15–13
95 RING DETECTION COUNT FOR DOWNLOADING 15
0
15 = number of rings before control picks up phone line
Refer to the chart below and program this field accordingly.
Phone
Module
Answering
Machine
Down-
loading
Field
95
Yes No No Set for value other than 0 (1–14). This will
enable the control panel to answer the phone
call. Otherwise, it will not be
possible to
access the phone module.
Yes Yes No Set for a value higher than the number of
r
ings for which the answering machine is set.
Example: If
machine is set for 4 rings, use a
value of 5 or higher. This is recommended so
that the phone module can still be accessed if
the answering machine is turned off and does
not answer the phone call.
Yes No Yes Set for value other than 0 (1–14).
Yes Yes Yes Enter 15. See note at left.
No No No Enter 0.
No Yes No Enter 0.
No No Yes Enter 1–14.
No Yes Yes Enter 15 to bypass answering machine.
NOTE:
If 15 is entered in field
95 to bypass an answering machine, and a 4285/4286 VIP
Module is included in the system, you should note the following:
When calling in from an off-premises phone, the user should make the initial call,
allow 1 to 3 rings only, then hang up. The user should then call again. The Phone
Module will now seize the line, and 2 long tones will sound, followed by the usual
voice prompt for the 2-digit access code. If this procedure is not followed, Phone
Module operation will not be possible.
96 INITIALIZE DOWNLOAD ID AND SUBSCRIBER ACCT. NO. FOR
DOWNLOADING
Pressing
96 initializes the system for downloading.
97 SET ALL PROGRAM FIELDS TO DEFAULT VALUES
Pressing
97 automatically loads all factory defaults and erases any
information previously programmed
98 EXITS PROGRAMMING MODE
P
revents
re-entry by Installer Code + [8] + [0] + [0]. To enter the
programming mode if
98 was used to exit, you must first power the system
down. Then power up again, and press
[
]
and
[#] at the same time, within 50
seconds of powering up.
99 EXITS PROGRAMMING MODE
Allows
re-entry by:
Installer Code
+
[8]
+
[0]
+
[
0
]
or by:
Pressing [
]
and
[#] at the same time, within 50 seconds of powering
the system up.